This paper proposes a modified $LLC$ resonant load configuration of a full-bridge inverter for induction-heating applications. The $LLC$ load configuration is a combination of a series inductor, a matching transformer, and an inductor and a capacitor connected in parallel. The output power is controlled using the asymmetrical voltage-cancellation technique. With the use of a phase-locked loop control, the operating frequency is automatically adjusted to maintain a small constant lagging phase angle under load-parameter variation during the heating process. The proposed configuration has the benefit of smaller inductance and inherent short-circuit protection capability in case a short circuit occurs at the induction coil or from transformer saturation. The validity of the proposed method is verified through computer simulation and hardware experiment at an operating frequency range of 108.7–110.6 kHz.
机译:本文提出了一种用于感应加热应用的全桥逆变器的改进的 $ LLC $ 谐振负载配置。 $ LLC $ 负载配置是串联电感器,匹配变压器以及连接在其中的电感器和电容器的组合平行。使用不对称电压消除技术控制输出功率。通过使用锁相环控制,可以在加热过程中自动调整工作频率,以在负载参数变化的情况下保持较小的恒定滞后相位角。所提出的配置具有较小的电感和固有的短路保护能力的优点,以防在感应线圈处发生短路或变压器饱和引起短路。通过计算机仿真和硬件实验在108.7–110.6 kHz的工作频率范围内验证了该方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号