摘要

In this paper, a hybrid control scheme for energy storage systems (ESS) and braking choppers for fault ride-through capability and a suppression of the output power fluctuation is proposed for permanent-magnet synchronous generator (PMSG) wind turbine systems. During grid faults, the dc-link voltage is controlled by the ESS instead of the line-side converter (LSC), whereas the LSC is exploited as a STATCOM to inject reactive current into the grid for assisting in the grid voltage recovery. The validity of the proposed system is verified by experimental results for a reduced-scale wind turbine simulator as well as simulation results for a 2-MW PMSG wind turbine system.
机译:本文针对永磁同步发电机(PMSG)风力涡轮机系统,提出了一种用于储能系统(ESS)和制动斩波器的混合控制方案,以实现故障穿越能力并抑制输出功率波动。在电网故障期间,直流链路电压由ESS而不是由线路侧转换器(LSC)控制,而LSC被用作STATCOM,以将无功电流注入电网,以帮助电网电压恢复。该系统的有效性通过针对小型风力发电机模拟器的实验结果以及2兆瓦PMSG风力发电机系统的仿真结果得到了验证。