首页> 外文期刊>IEEE Transactions on Industrial Electronics >Distributed IPT Systems for Dynamic Powering: Misalignment Analysis
【24h】

Distributed IPT Systems for Dynamic Powering: Misalignment Analysis

机译:用于动态供电的分布式IPT系统:失准分析

获取原文
获取原文并翻译 | 示例
           

摘要

This paper looks into the problem of misalignment in distributed inductive power transfer systems. The idea of varying mutual inductance longitudinally referred to as longitudinal misalignment is introduced here. The analytical expressions for both lateral and longitudinal misalignment are derived. Experimental validation of the theory developed is also performed. In case of conventional rectangular coils, the vertical sections are not symmetrical. This was observed in the mutual inductance profile experimentally, and the concept of “Edge Effect” was introduced to explain the same. An inductor with symmetrical ends was constructed to tackle this problem.
机译:本文研究了分布式感应式电力传输系统中的未对准问题。这里介绍了纵向改变互感的想法,即纵向未对准。导出了横向和纵向未对准的解析表达式。还对开发的理论进行了实验验证。在常规矩形线圈的情况下,垂直部分不对称。在互感曲线中通过实验观察到了这一点,并引入了“边缘效应”的概念对此进行了解释。为了解决这个问题,设计了具有对称端部的电感器。