This paper presents a real-time diagnostic algorithm for insulated-gate bipolar transistor open-circuit faults in three-level neutral-point-clamped rectifiers. This algorithm is based on the instant voltage error in the converter and requires only signals already available to the control system, avoiding the use of additional hardware. The algorithm is independent from the load and from the used control strategy and provides very fast detection and identification of the fault, with diagnostic times as low as two sample periods (in favorable conditions). Experimental results are presented for the operation of the rectifier with two distinct control and modulation strategies and in different conditions. Results show the algorithm's speed, effectiveness, and robustness.
机译:本文提出了一种用于三级中性点钳位整流器中绝缘栅双极型晶体管开路故障的实时诊断算法。该算法基于转换器中的瞬时电压误差,并且仅需要控制系统已经可用的信号,从而避免了使用其他硬件。该算法与负载和所使用的控制策略无关,并且可以非常快速地检测和识别故障,诊断时间低至两个采样周期(在有利条件下)。给出了两种不同控制和调制策略以及在不同条件下对整流器进行操作的实验结果。结果表明该算法的速度,有效性和鲁棒性。