首页> 外文期刊>Indoor and built environment >Characterization of Indoor Air Bioaerosols in an Electrical Headquarter Building
【24h】

Characterization of Indoor Air Bioaerosols in an Electrical Headquarter Building

机译:电气总部大楼中的室内空气生物气溶胶的表征

获取原文
获取原文并翻译 | 示例
       

摘要

Bioaerosols may produce poor indoor air quality and affect the health of the building occupants. We identified bacteria and fungi from bioaerosols and determined the microbial density values by the impac-tion method on solid surface in 104 locations distributed in 26 floors from an electrical headquarter building. Indoor contamination was interpreted as follow: >500CFUm~(-3), indoor microbial density higher than the outdoor microbial density and pathogenic isolate. Results showed bacterial density values from 28CFUm~(-3) to 522 CFU m~(-3) from which 18 theatres exceeded the non-contaminated density range, overcame the outdoor average density value (198 CFU m~(-3)) or depicted the presence of the pathogenic bacteria Staphylococcus aureus and/or Staphylococcus sapro-phyticus. Other bacterial opportunistic pathogens were isolated. Airborne fungal detection depicted density values from 2CFUm~(-3) to 800 CFU m~(-3). Fungal density values exceeding the non-contamination range were detected in 12 theatres distributed in 7 floors. No pathogenic fungi were detected. However, opportunistic pathogen or sick building syndrome (SBS)-associ-ated fungal isolates, particularly Penicillum and Aspergillus, were widely distributed in almost all floors. Even though we did not associate our findings with SBS and building-related illness (BRI), we showed that this culture-based analysis proved to be an adequate way to determine the microbiological indoor air quality.
机译:生物气溶胶可能产生差的室内空气质量,并影响建筑物居民的健康。我们从生物气溶胶中鉴定出细菌和真菌,并通过冲击方法在位于电气总部大楼26层的104个位置的固体表面上,通过撞击法确定了微生物的密度值。室内污染解释为:> 500CFUm〜(-3),室内微生物密度高于室外微生物密度和病原菌。结果表明,细菌密度值从28CFUm〜(-3)到522 CFU m〜(-3),其中18个影院超出了非污染密度范围,超过了室外平均密度值(198 CFU m〜(-3))或描绘了病原细菌金黄色葡萄球菌和/或腐生葡萄球菌的存在。分离出其他细菌机会病原体。机载真菌检测描述了从2CFUm〜(-3)到800 CFU m〜(-3)的密度值。在分布于7层楼的12家影院中检测到了超过无污染范围的真菌密度值。未检测到致病真菌。但是,机会病原体或病态建筑综合症(SBS)相关的真菌分离株,尤其是青霉和曲霉,几乎分布在所有楼层。即使我们没有将研究结果与SBS和建筑物相关疾病(BRI)相关联,我们也证明了这种基于文化的分析被证明是确定室内微生物微生物质量的适当方法。

著录项

  • 来源
    《Indoor and built environment》 |2013年第6期|910-919|共10页
  • 作者单位

    Oil and Air Microbiology Laboratory. Cell Biology Department, Simon Bolivar University, Valle de Sartenejas, Apto, 89.000, Caracas 1080-A. Venezuela;

    Cell Biology Department, Simon Bolivar University, Caracas, Venezuela;

    Electricidad de Caracas, Corpoelect, Caracas, Venezuela;

    Electricidad de Caracas, Corpoelect, Caracas, Venezuela;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Bioaerosols; Indoor air; Bacteria; Fungi; Microbial air quality;

    机译:生物气溶胶;室内空气菌;菌类;微生物空气质量;
  • 入库时间 2022-08-17 23:05:00