首页> 外文期刊>Indoor Air >Ventilation in day care centers and sick leave among nursery children
【24h】

Ventilation in day care centers and sick leave among nursery children

机译:托儿所的日托中心通风和病假

获取原文
获取原文并翻译 | 示例
           

摘要

Several studies have reported poor indoor air quality (IAQ) in day care centers (DCCs), and other studies have shown that children attending them have an increased risk of respiratory and gastrointestinal infections. The aim of this study was to investigate whether there is an association between ventilation in DCCs and sick leave among nursery children. Data on child sick leave within an 11-week period were obtained for 635 children attending 20 DCCs. Ventilation measurements included three proxies of ventilation: air exchange rate (ACR) measured with the decay method, ACR measured by the perfluorocarbon tracer gas (PFT) method, and CO2 concentration measured over a 1-week period. All but two DCCs had balanced mechanical ventilation system, which could explain the low CO2 levels measured. The mean concentration of CO2 was 643 ppm, exceeding 1000 ppm in only one DCC. A statistically significant inverse relationship between the number of sick days and ACR measured with the decay method was found for crude and adjusted analysis, with a 12% decrease in number of sick days per hour increase in ACR measured with the decay method. This study suggests a relationship between sick leave among nursery children and ventilation in DCCs, as measured with the decay method.
机译:几项研究报告说,日托中心(DCC)的室内空气质量(IAQ)较差,其他研究表明,就诊的儿童患呼吸道和胃肠道感染的风险增加。这项研究的目的是调查DCC中的通气与托儿所患病假之间是否存在关联。获得了参加20个DCC的635名儿童在11周内的病假数据。通风测量包括三个通风代理:通过衰减方法测量的空气交换率(ACR),通过全氟化碳示踪气体(PFT)方法测量的ACR和在1周内测量的CO2浓度。除两个DCC外,所有DCC均具有平衡的机械通风系统,这可以解释所测得的CO2含量低。 CO2的平均浓度为643 ppm,仅在一个DCC中就超过了1000 ppm。对于粗略和调整后的分析,发现使用衰减方法测得的病假天数与ACR之间存在统计学上显着的反比关系,使用衰减方法测得的ACR每小时病假天数减少了12%。这项研究表明,使用衰减法测量的,托儿所患病假与DCC通风之间的关系。

著录项

  • 来源
    《Indoor Air》 |2016年第2期|157-167|共11页
  • 作者单位

    Department of Construction and Health, Danish BuildingResearch Institute, Aalborg University, A.C. MeyersVaenge 15, 2450 Copenhagen SV, Denmark;

    Department of Public Health,Center for Epidemiology and Screening, CopenhagenUniversity, Copenhagen, Denmark;

    Departments of Infection Control and Clinical Microbiology, CopenhagenUniversity Hospital (Rigshospitalet), Copenhagen,Denmark;

    DHI, Hoersholm, Denmark;

    Department of Construction and Health, DanishBuilding Research Institute, Aalborg University,Copenhagen, Denmark;

    Department of Construction and Health, DanishBuilding Research Institute, Aalborg University,Copenhagen, Denmark;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air change rate; Absenteeism; Child care; Decay; Perfluorocarbon tracer gas; Carbon dioxide.;

    机译:换气率;旷工;儿童保育;衰变;全氟化碳示踪气体;二氧化碳。;