The discusser would like to congratulate the authors — Mr Ravi and Vasant Kanitkar — for throwing light on a very practical topic, which is very important to the design of multi-storey buildings of our country. The draft code of IS 1893, which was under circulation for more than 2 to 3 years, did not contain clause 7.10. This clause was introduced in the final code only after witnessing the failure of several multistorey buildings during the 2001 Bhuj earthquake. To my knowledge the factor of 2.5 specified in clause 7.10.3(a) and the factor of 1.5 specified in clause 7.10.3(b) of the code were chosen arbitrarily without any scientific investigations. Hence this paper, which compares the base shears based on this approach given by the code with the results of an inelastie analysis, assumes greater importance.
机译:讨论者要祝贺作者Ravi先生和Vasant Kanitkar先生阐明了一个非常实用的话题,这对我国多层建筑的设计非常重要。流通超过2至3年的IS 1893法规草案未包含第7.10条。仅在目睹2001年普杰地震期间几栋多层建筑物倒塌后,才在最终代码中引入了此条款。据我所知,本规范第7.10.3(a)条规定的系数2.5和第7.10.3(b)条规定的系数1.5是在没有任何科学调查的情况下任意选择的。因此,本文将基于代码给出的这种方法的基础剪力与inelastie分析的结果进行了比较,因此具有更大的重要性。