首页> 外文期刊>The Indian concrete journal >PERFORMANCE OF GALVANIZED STEEL REBARS IN CONCRETE
【24h】

PERFORMANCE OF GALVANIZED STEEL REBARS IN CONCRETE

机译:镀锌钢筋混凝土的性能

获取原文
获取原文并翻译 | 示例
           

摘要

In this experimental investigation, the performance of galvanized steel rebars was assessed for its use in construction. The corrosion control efficacy of galvanized steel reinforcement (rebars) and the influence of galvanization on mechanical properties of steel rebars were studied. The tests were conducted following the Indian / ASTM standards and procedures followed by earlier researchers. It was noticed that galvanization provides adequate sacrificial protection to steel rebars in the chemical resistance test, open circuit potential test, and macrocell corrosion test in the tested duration. The performance of the galvanized rebars was 1.75 to 2.60 times higher than the uncoated rebars in the highly accelerated electrochemical corrosion conditions. The bond strength values for galvanized rebars were similar when compared with uncoated rebars. Impact and adhesion test results also indicate that galvanized rebars comply with the codal requirements of Indian and ASTM Standards. The coating damage of 1% did not adversely influence the corrosion resistance properties of galvanized rebars.
机译:在这项实验研究中,评估了镀锌钢筋的性能,以便在建设中使用。研究了镀锌钢筋(钢筋)的腐蚀控制效果及镀锌对钢筋力学性能的影响。在印度/ ASTM标准和程序之后进行的测试进行了测试。注意到,镀锌为耐化学性试验,开路电位试验和宏小区腐蚀试验提供了足够的牺牲保护,在测试的持续时间内为钢钢筋提供了足够的牺牲保护。镀锌钢筋的性能比高度加速的电化学腐蚀条件下的未涂层钢筋高1.75至2.60倍。与未涂层的钢筋相比,镀锌钢筋的债券强度值类似。撞击和粘附试验结果还表明,镀锌钢筋符合印度和ASTM标准的编码要求。 1%的涂层损伤不会对镀锌钢筋的耐腐蚀性性能产生不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号