Arc duration of silver contacts was measured with fixed short gap under the condition of different constant gaps and different constant currents, which are close to the minimum arc current of the contact material. The results indicated that the arc occurred even at the current less than the minimum arc current. The arc duration varies in different operations at the same testing condition and it distributes exponentially in the time range up to 100 microseconds. The time constant τ and the extinction rate λ of the distribution were calculated, and related to the arc current. It was assured by silver electrode arc that, even below the so-called minimum arc current, arc ignition may occur but, in this case, the arc duration is momentary, and, as the arc current decreases, the arc extinction rate becomes large.
机译:在不同的恒定间隙和不同的恒定电流的条件下,以固定的短间隙测量银触点的电弧持续时间,该常数接近于接触材料的最小电弧电流。结果表明,即使电流小于最小电弧​​电流,也会发生电弧。电弧持续时间在相同测试条件下的不同操作中会有所不同,并且在高达100微秒的时间范围内呈指数分布。计算出时间常数τ和消光率λ,并与电弧电流有关。通过银电极电弧可以确保,即使低于所谓的最小电弧电流,也可能会发生电弧着火,但是在这种情况下,电弧持续时间是瞬时的,并且随着电弧电流的减小,灭弧率变大。