The Japanese regulation and rules on in-house broadband and high speed power line communication (PLC) were enforced on 4 October 2006, and supposed, with 99% probability, to suppress the radiated electric field (REF) at a distance of 10m or 30m, below the ambient noise level by restricting the common mode (CM) current measured by an ISN with LCL=16dB. However actual excess of REF is higher than the ambient noise level by more than 40dB. Thus we measured the REF, forward/reflected currents and so on by using a few commercially available PLC modems in order to investigate the origin of the excess REF and possible problems of the technical basis for the Japanese PLC modem. In addition, we propose to improve values of the technical basis.%我が国の屋内広帯域・高速電力線搬送通信(PLC)設備の技術基準は、LCL=16dBのISNを用いて測定したコモンモード(CM)電流の許容値により、99%の確率で実環境に於ける漏洩電界が離隔距離10m及び30mで周囲雑音以下に抑制出来るとしている。しかし、現実には、周囲雑音から40dB以上超過する漏洩電界が発生する。この漏洩電界の超過原因を探究する為に、技術基準を満たす複数のPLCモデムを試用して漏洩電界や進行波・反射波電流その他のパラメータを測定し、技術基準の問題点を考察し、この技術基準値の見直しを提案する。
机译:日本关于室内宽带和高速电力线通信(PLC)的法规和规则于2006年10月4日强制实施,并被认为以99%的概率抑制10m或30m距离的辐射电场(REF)。 ,通过限制LCL = 16dB的ISN测得的共模(CM)电流,使其低于环境噪声水平,但是实际的REF超出环境噪声水平40dB以上,因此我们测量了REF的正向/反射为了研究过剩的REF的由来以及日本PLC调制解调器的技术基础可能存在的问题,通过使用一些市售的PLC调制解调器等电流,此外,我们建议提高技术基础的价值。由于使用LCL = 16 dB的ISN测量的共模(CM)电流的允许值,室内宽带高速电力线载波通信(PLC)设备的技术标准是真实环境中泄漏电场的概率为99%。据说可以在10 m和30 m的分离距离下抑制在环境噪声以下。但是,实际上,会产生来自环境噪声的超过40 dB的泄漏电场。为了调查导致泄漏电场超标的原因,尝试了多个符合技术标准的PLC调制解调器,并测量了泄漏电场,行波/反射波电流等参数,并考虑了技术标准存在的问题。我们建议审查技术标准值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号