In this paper, the basic characteristics of electric field and current density distributions in the human body resulting from 60Hz contact currents are demonstrated. First, the numerical method which is partly modified from SPFD method is proposed, and the validity of the improved method is confirmed by comparing with measurements with a simple model. Then, electric fields and current densities in the human body are calculated by three pathways of contact currents: left palm to both feet, right palm to both feet, and right palm to left palm. For contact current of 0.5mA (the reference level set by the ICNIRP), the maximum value of current density in spinal cord is five times greater than the basic restriction of 2mA/m2. In addition, it is found from results that 33 ~ 40% of contact currents flow through the heart under three pathways.%本論文では,人体数値モデルに電位の異なる電極を配置した場合に体内における電界・電流密度の基本的な分布特性を示している。まず,SPFD 法を一部改良した数値解析手法を紹介し,直方体型の単純な生体媒質に対して測定結果と解析結果を比較検討することで数値解析コードの妥当性を検証した。次に,日本人成人男性の数値モデルを用いて,①左手のひら一両足の裏,②右手のひら一両足の裏,③右手のひら一左手のひらの3パターンの電極配置を考え,0.5mA の接触電流を流した場合におけるモデル内の電界.電流密度を数値解析した。解析結果から,0.5mA の接触電流に対して神経(脊髄)の電流密度の最大値はICNIRP の基本制限(2mA/m~2)を5倍程度上回ることが分かった。また,3つの解析パターンで心臓を通過する電流の割合は33~40%であり,左手のひら一両足の裏の場合が最も大きい割合となることが分かった。