In the safety evaluation for base-station workers, it is necessary to master the near-field electric field distribution in the base-station neighborhood. In this study, we discussed a two-step approach to estimate the near-field electric field distribution from the measured electric field data on a cylinder containing the base-station antenna. At first we estimated the antenna current distribution by dividing the antenna into many small dipoles. Then we estimated the near-field electric field distribution by using the antenna current distribution. The simulation results showed that the electric field can be estimated within a relative error of 6%. We also applied this method to a realistic vertical linear array antenna and compared the estimated and the measured electric field distributions outside the measuring cylinder. They exhibited good agreement. This agreement suggests the validity of the estimated near-field electric field distribution inside the measuring cylinder.%基地局作業者の安全性評価において,基地局アンテナ近傍の電界強度の把握が不可欠である.本研究では,基地局アンテナを囲む円筒面上の電界接線成分を測定し,それを用いて,まずアンテナ放射部を微小ダイポールの集合と見なし,各微小ダイポールの電流を推定することでアンテナ上の電流分布を求めた.次に,求めた電流分布から測定困難な基地局アンテナ近傍の電界分布の推定を行った.複数の半波長ダイポールからなる垂直リニアアレイアンテナに対してシミュレーションで検討した結果,6%以内の相対誤差で電界分布を推定できることがわかり,また,実際の基地局用垂直リニアアレイアンテナに適用した結果,円筒外側の電界分布が実測値と概ね一致することが確認でき,それ故に円筒内側の近傍電界分布の推定結果も合理であると推察できた.