首页> 外文期刊>IEEE Transactions on Signal Processing >Accuracy vs. Resolution in Radio Tomography
【24h】

Accuracy vs. Resolution in Radio Tomography

机译:断层扫描的准确性与分辨率

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Radio tomographic imaging (RTI) has recently been proposed for tracking object location via radio waves without requiring the objects to transmit or receive radio signals. The position is extracted by inferring which voxels are obstructing the various radio links in a dense wireless sensor network. This paper derives an analytic expression for the image accuracy (error per voxel) for each of 5 published RTI system models. The formulae show the effects of weight model choice, voxel size, number of sensors, and degree of regularization on the Cramér-Rao Lower Bound (CRLB). This enables analysis of the tradeoffs between these parameters in system design, particularly between image accuracy and image resolution. The theoretical results agree well with simulations, and the new theory is used to interpret an experimental scenario.
机译:最近已经提出了无线电层析成像(RTI),用于经由无线电波跟踪物体的位置,而不需要物体发送或接收无线电信号。通过推断哪些体素正在阻塞密集的无线传感器网络中的各种无线电链路来提取位置。本文针对5种已发布的RTI系统模型中的每一种得出了图像精度(每个体素的误差)的解析表达式。公式显示了权重模型选择,体素大小,传感器数量以及正则化程度对Cramér-Rao下界(CRLB)的影响。这使得能够分析系统设计中这些参数之间的折衷,特别是图像精度和图像分辨率之间的折衷。理论结果与仿真非常吻合,并且使用新理论来解释实验场景。