摘要

The application of the average current mode control (ACMC) to a new type of very efficient post-regulator is studied in this paper. This post-regulator, called series-switching post-regulator (SSR), has been proposed to improve the dynamic response series-switching of power factor correctors (PFC), The post-regulator exhibits very high efficiency due to the fact that only a part of the total power undergoes a power conversion process. Using ACMC, the bandwidth of the post-regulator increases in relation to the one obtained when a conventional voltage-mode control (with or without feedforward) is used. As a result, the attenuation of the input voltage ripple (100-120 Hz) increases and, a lower bulk capacitor can be used to obtain a low voltage ripple at the output, which is extremely important when a battery is connected at the output. This is rather common in distributed power supply systems.
机译:本文研究了平均电流模式控制(ACMC)在新型高效后稳压器中的应用。为了改善功率因数校正器(PFC)的动态响应串联开关,已经提出了这种称为串联开关后稳压器(SSR)的后调节器。由于只有一个总功率的一部分经历了功率转换过程。使用ACMC,后调节器的带宽相对于使用常规电压模式控制(带或不带前馈)时获得的带宽增加。结果,输入电压纹波(100-120 Hz)的衰减增加,并且可以使用较小的大容量电容器在输出端获得低电压纹波,当在输出端连接电池时,这非常重要。这在分布式电源系统中相当普遍。