首页> 外文期刊>IEEE Transactions on Power Electronics >Arc Fault Detection Scheme for 42-V Automotive DC Networks Using Current Shunt
【24h】

Arc Fault Detection Scheme for 42-V Automotive DC Networks Using Current Shunt

机译:使用电流分流器的42V汽车直流网络的电弧故障检测方案

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction of higher dc system voltage distribution networks, such as the 42-V PowerNet in future passenger vehicles appears to be an unavoidable consequence of meeting the increasing future electrical power demand. Higher voltage electrical distribution networks in vehicles force considerable component and system changes regarding electrical safety and reliability. In the event of an arc fault, e.g., when a wire is pinched or cut, or disengaged terminals under load etc., the resulting current may be significantly lower than the trip current of the protection devices such as fuses and circuit breakers. In these cases either the fault is cleared late (depending on the time/current characteristics of the fuse) or, in some cases the fault may not be cleared at all. A cost effective arc fault detection scheme using input side current shunt was developed, built, and tested with different loads including motor loads to clear both parallel and series arc faults in a 42-V dc network. This paper presents the details of the developed arc fault detection scheme and test results under several fault conditions.
机译:在未来的乘用车中引入更高的直流系统电压配电网络,例如42V PowerNet,似乎是满足未来不断增长的电力需求的必然结果。车辆中较高的配电网络迫使有关电气安全性和可靠性的组件和系统发生重大变化。在发生电弧故障的情况下,例如,当电线被捏住或切断时,或负载下端子脱离时,所产生的电流可能会大大低于保险丝和断路器等保护装置的跳闸电流。在这些情况下,故障可能会被清除(取决于保险丝的时间/电流特性),或者在某些情况下根本无法清除故障。开发,构建和测试了一种使用输入侧电流分流器的经济有效的电弧故障检测方案,该方案可在包括电机负载在内的不同负载下进行测试,以清除42V直流网络中的并联和串联电弧故障。本文详细介绍了已开发的电弧故障检测方案和在几种故障条件下的测试结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号