The extended commutation cell is a four-port four-switch cell that allows for bidirectional energy transport in two orthogonal directions throughout the cell. By cascading multiple cells, a multilevel converter can be constructed with a high number of levels. The voltage across each cell capacitor can be adjusted independently of the load, resulting in high flexibility in output levels. This paper presents an improved method for capacitor voltage control, based on a system model and the measured output current. The proposed method is analyzed and verified on a $4.4text{-}mathrm{k}mathrm{W}$ eight-level dc-ac converter. The obtained reduction in capacitor voltage ripple is more than $75%$.
机译:扩展换向单元是一个四端口四开关单元,它允许在整个单元中沿两个正交方向进行双向能量传输。通过级联多个单元,可以构建具有大量电平的多电平转换器。每个单元电容器两端的电压可以独立于负载进行调节,从而在输出电平方面具有高度的灵活性。本文基于系统模型和实测输出电流,提出了一种改进的电容电压控制方法。在$ 4.4 text {-} mathrm {k} mathrm {W} $八电平DC-AC转换器上对提出的方法进行了分析和验证。所获得的电容器电压纹波降低超过$ 75%$。