摘要

Burst mode control techniques have been studied for LLC resonant dc-dc converters to improve power conversion efficiencies at light load conditions. However, there are not many studies about how to detect the load conditions at burst mode not even at normal mode, at the primary side of LLC resonant dc-dc converters. In this paper, we propose and implement a lossless load detection technique for normal and burst modes by a novel average input current sensing method at the primary side of LLC resonant converters. Detailed theoretical analysis at normal and burst modes is presented and a load detection circuit is proposed with the consideration of integrated circuits. To verify the analysis, an LLC resonant offline converter with 400 V input and 16 V/10 A output is simulated using PSIM and a prototype board is built. The experimental results show that the proposed load detection technique is valid and practical. As a result, an automatic burst mode control for LLC resonant converters at light load conditions is realized with the proposed average input current sensing method.
机译:已经针对LLC谐振DC-DC转换器研究了突发模式控制技术,以提高轻载条件下的功率转换效率。但是,关于如何在LLC谐振DC-DC转换器的初级侧,即使在正常模式下也无法检测突发模式下的负载条件的研究并不多。在本文中,我们提出并通过LLC谐振转换器初级侧的一种新颖的平均输入电流检测方法,针对正常模式和突发模式提出并实现了一种无损负载检测技术。给出了正常模式和突发模式下的详细理论分析,并提出了考虑集成电路的负载检测电路。为了验证分析,使用PSIM对具有400 V输入和16 V / 10 A输出的LLC谐振离线转换器进行了仿真,并构建了原型板。实验结果表明,所提出的负荷检测技术是有效和实用的。结果,利用所提出的平均输入电流感测方法实现了在轻载条件下对LLC谐振转换器的自动突发模式控制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号