首页> 外文期刊>IEEE Transactions on Power Electronics >PWM Frequency Noise Cancellation in Two-Segment Three-Phase Motor Using Parallel Interleaved Inverters
【24h】

PWM Frequency Noise Cancellation in Two-Segment Three-Phase Motor Using Parallel Interleaved Inverters

机译:使用并联交错式逆变器的两段式三相电动机中的PWM频率噪声消除

获取原文
获取原文并翻译 | 示例
       

摘要

This paper proposed a novel method for two-segment three-phase motor to eliminate the harmonics nearby pulsewidth modulation (PWM) frequency. Due to PWM technique and switching losses considerations, ear-piercing high-frequency electromagnetic noise in drive system is common. By using magnetically coupled inductors (MCIs) and interleaved technique, the proposed novel method is able to remove the high-frequency harmonics located nearby the PWM frequency and other odd multiples in two-segment three-phase motor. With this method, the unpleasant acoustic noise could be removed when the PWM frequency is selected near 10 kHz. The size of MCIs mainly depends on the PWM frequency harmonic currents rather than the fundamental frequency currents. Thus, its size is very small compared with LC filter. Moreover, this method remains the control dynamics of two-segment three-phase motor without additional inductance for fundamental-frequency currents. The shift phase of two inverters PWM carriers is pi, which is simple to implement. Finally, the effectiveness of the proposed method is verified by experimental results.
机译:本文提出了一种用于两段式三相电动机的新型方法,以消除脉冲宽度调制(PWM)频率附近的谐波。由于PWM技术和开关损耗的考虑,驱动系统中刺耳的高频电磁噪声很常见。通过使用磁耦合电感器(MCI)和交错技术,提出的新方法能够去除位于两段式三相电动机中PWM频率附近的高频谐波和其他奇数倍。使用这种方法,当选择PWM频率接近10 kHz时,可以消除令人不快的噪声。 MCI的大小主要取决于PWM频率谐波电流,而不是基本频率电流。因此,与LC滤波器相比,其尺寸非常小。此外,该方法保持了两段式三相电动机的控制动力学特性,而没有针对基频电流的附加电感。两个反相器PWM载波的移位相位为pi,易于实现。最后,实验结果验证了该方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号