A new control algorithm for the three-phase buck rectifier with an input filter is developed. The algorithm employs a separate control loop for compensation of the input current displacement factor in steady-state, in addition to the standard output voltage regulation loop. The algorithm allows separate design of the input filter and of closed-loop output voltage control. The design procedure is explained and illustrated with an example. The algorithm is verified experimentally on a 1 kW, 100 kHz, three-phase isolated buck converter.
机译:针对带输入滤波器的三相降压整流器,提出了一种新的控制算法。除了标准输出电压调节回路外,该算法还采用了单独的控制回路来补偿稳态下的输入电流位移因数。该算法允许分别设计输入滤波器和闭环输出电压控制。举例说明和说明设计过程。该算法在1 kW,100 kHz三相隔离降压转换器上进行了实验验证。