首页> 外文期刊>IEEE Transactions on Nuclear Science >Performance of the front end electronics and data acquisition system for the SLD Cherenkov ring imaging detector
【24h】

Performance of the front end electronics and data acquisition system for the SLD Cherenkov ring imaging detector

机译:SLD Cherenkov环形成像探测器前端电子和数据采集系统的性能

获取原文
获取原文并翻译 | 示例
           

摘要

The front-end electronics and data acquisition system for the SLD barrel Cherenkov ring imaging detector (CRID) are described. The specifications for this system require a 1% charge division measurement on single e/sup -/ pulses from a wire chamber in the presence of much larger signals. Fast recovery from saturating pulses and noise levels below 2000 electrons root-mean-square for single electron pulses are required. Noise and system performance results are presented for the initial SLD engineering run data.
机译:描述了用于SLD镜筒Cherenkov环形成像探测器(CRID)的前端电子和数据采集系统。该系统的规格要求在存在大得多的信号的情况下,对来自导线室的单个e / sup-/脉冲进行1%的电荷分配测量。需要从饱和脉冲和低于2000个电子均方根的噪声水平快速恢复单个电子脉冲。给出了初始SLD工程运行数据的噪声和系统性能结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号