Development of an intraoperative gamma camera based on a 256-pixel mercuric iodide detector array

机译:基于256像素碘化汞探测器阵列的术中伽马相机的开发

获取原文
获取原文并翻译 | 示例
           

摘要

A 256-element mercuric iodide (HgI/sub 2/) detector array has been developed which is intended for use as an intraoperative gamma camera (IOGC). The camera is specifically designed for use in imaging gamma-emitting radiopharmaceuticals (such as 99m-Tc labeled Sestamibi) incorporated into brain tumors in the intraoperative surgical environment. The system is intended to improve the success of tumor removal surgeries by allowing more complete removal of subclinical tumor cells without removal of excessive normal tissue. The use of HgI/sub 2/ detector arrays in this application facilitates construction of an imaging head that is very compact and has a high SNR. The detector is configured as a cross-grid array. Pixel dimensions are 1.25 mm squares separated by 0.25 mm. The overall dimension of the detector is 23.75 mm on a side. The detector thickness is 1 mm which corresponds to over 60% stopping at 140 keV. The array has good uniformity with average energy resolution of 5.2/spl plusmn/2.9% FWHM at 140 keV (best resolution was 1.9% FWHM). Response uniformity (/spl plusmn//spl sigma/) was 7.9%. A study utilizing realistic tumor phantoms (uptake ratio varied from 2:1 to 100:1) in background (1 mCi/l) was conducted. SNRs for the reasonably achievable uptake ratio of 50:1 were 5.61 /spl sigma/ with 1 cm of background depth ("normal tissue") and 2.74 /spl sigma/ with 4 cm of background for a 6.3 /spl mu/l tumor phantom (/spl sim/270 nCi at the time of the measurement).
机译:已开发出一种256元素的碘化汞(HgI / sub 2 /)检测器阵列,旨在用作术中伽马相机(IOGC)。该摄像机专门设计用于对术中手术环境中掺入脑肿瘤的发射伽马射线的放射性药物(例如标记为Sestamibi的99m-Tc)进行成像。该系统旨在通过允许更完全地去除亚临床肿瘤细胞而不去除过多的正常组织来提高肿瘤去除手术的成功率。 HgI / sub 2 /检测器阵列在此应用中的使用有利于构造非常紧凑且具有高SNR的成像头。检测器配置为交叉网格阵列。像素尺寸为1.25毫米的正方形,相隔0.25毫米。探测器的整体尺寸在侧面为23.75毫米。检测器厚度为1 mm,相当于在60 keV处停止超过60%。该阵列具有良好的均匀性,在140 keV时的平均能量分辨率为5.2 / spl plusmn / 2.9%FWHM(最佳分辨率为1.9%FWHM)。响应均匀度(/ spl plusmn // spl sigma /)为7.9%。进行了利用背景(1 mCi / l)的逼真的肿瘤模型(摄取率从2:1到100:1不等)进行的研究。对于6.3 / spl mu / l肿瘤模型,合理可达到的50:1摄取比的SNR为5.61 / spl sigma /(背景深度为1厘米)(“正常组织”)和2.74 / spl sigma /(背景为4 cm)。 (/ spl sim / 270 nCi在测量时)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号