Calibration of Dual-Ended Readout of Axially Oriented 100-mm-Long LYSO Crystals for Use in a Compact PET System

机译:用于紧凑型PET系统的轴向定向100mm长LYSO晶体的双端读数校准

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We are investigating the use of 100-mm-long axially oriented scintillator crystals read out at either end by position-sensitive photomultiplier tubes (PSPMTs) for application to a small-animal positron emission tomography (PET) system. A system design of this type requires a robust and efficient calibration of the detector response in the light-sharing direction in order to accurately decode the location of photon interaction. In this paper, we evaluate methods for determining the axial positioning calibration of dual-ended readout of $2times 2times 100{hbox{-mm}}^{3}$ lutetium yttrium oxyorthosilicate (LYSO) crystals wrapped in either Teflon or 3M Enhanced Specular Reflector (ESR). We compare a collimated irradiation method to a uniform irradiation method recently proposed by Shao. In the collimated irradiation method, an electronically collimated beam of 511-keV photons aimed perpendicular to the long axis of the crystal is used to irradiate the crystal at nine locations in steps of 1 cm. The ratio of the two PMT signals at each irradiation position is used to give the axial-positioning calibration relating ratio signal to position. In the method by Shao, the crystal was irradiated using either a uniform $^{68}$ Ge line source, a $^{22}$ Na point source, or the intrinsic background activity in the LYSO. To check the validity of both calibration methods for unbalanced detectors, three voltage variations ranging from 750–800 V were used for the two PMTs. For cases with balanced detector gains, the calibration curves obtained using uniform irradiation and Shao's method agreed very well with the reference curve obtained from the collimated irradiation measurements. For the case with detectors that had unbalanced gain, agreement between uniform irradiation and - ollimated irradiation methods was only achieved if the trigger threshold energies of the two PMTs were adjusted to give similar single-event rates in both PMTs. These findings suggest that Shao's calibration method using uniform irradiation will provide a simple, accurate, and rapid method for calibration of 100-mm-long dual-ended readout detectors.
机译:我们正在研究使用位置敏感光电倍增管(PSPMT)在两端读取100毫米长的轴向闪烁体晶体的方法,以将其应用于小动物正电子发射断层扫描(PET)系统。这种类型的系统设计要求在光共享方向上对检测器响应进行鲁棒而有效的校准,以便准确地解码光子相互作用的位置。在本文中,我们评估了确定$ 2×2×100 {hbox {-mm}} ^ {3} $ oxy氧基正硅酸钇钇晶体包裹的特氟隆或3M增强镜面双端读数的轴向定位校准方法。反射器(ESR)。我们将Shao最近提出的准直照射方法与均匀照射方法进行了比较。在准直照射方法中,垂直于晶体的长轴瞄准的511keV光子的电子准直束用于以1cm的步长在九个位置处照射晶体。在每个照射位置的两个PMT信号的比率用于给出将比率信号与位置相关的轴向定位校准。在Shao的方法中,使用均匀的$ ^ {68} $ Ge线源,$ ^ {22} $ Na点源或LYSO中固有的背景活性来辐照晶体。为了检查两种不平衡检测器校准方法的有效性,两个PMT使用了750-800 V范围内的三个电压变化。对于探测器增益平衡的情况,使用均匀辐射和Shao方法获得的校准曲线与从准直辐射测量获得的参考曲线非常吻合。对于具有不平衡增益的检测器的情况,只有将两个PMT的触发阈值能量调整为在两个PMT中提供相似的单事件发生率,才能实现均匀照射和柔光照射方法之间的一致性。这些发现表明,邵氏使用均匀辐射的校准方法将为校准100毫米长的双端读数检测器提供一种简单,准确和快速的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号