In this work, a new extended-length parallel-plate ionization chamber was tested in the standard radiation qualities for computed tomography established according to the half-value layers defined at the IEC 61267 standard, at the Calibration Laboratory of the Instituto de Pesquisas Energéticas e Nucleares (IPEN). The experimental characterization was made following the IEC 61674 standard recommendations. The experimental results obtained with the ionization chamber studied in this work were compared to those obtained with a commercial pencil ionization chamber, showing a good agreement. With the use of the PENELOPE Monte Carlo code, simulations were undertaken to evaluate the influence of the cables, insulator, PMMA body, collecting electrode, guard ring, screws, as well as different materials and geometrical arrangements, on the energy deposited on the ionization chamber sensitive volume. The maximum influence observed was 13.3% for the collecting electrode, and regarding the use of different materials and design, the substitutions showed that the original project presented the most suitable configuration. The experimental and simulated results obtained in this work show that this ionization chamber has appropriate characteristics to be used at calibration laboratories, for dosimetry in standard computed tomography and diagnostic radiology quality beams.
机译:在这项工作中,在PesquisasEnergéticase校准实验室根据IEC 61267标准定义的半值层建立了用于计算机断层扫描的标准辐射质量的新型加长平行板电离室。核能(IPEN)。实验特性是根据IEC 61674标准建议进行的。用这项工作研究的电离室获得的实验结果与用商用铅笔电离室获得的结果进行了比较,显示出很好的一致性。使用PENELOPE蒙特卡洛代码,进行了仿真,以评估电缆,绝缘体,PMMA主体,收集电极,保护环,螺钉以及不同的材料和几何布置对电离沉积的能量的影响。腔室敏感容积。对于集电极,观察到的最大影响为13.3%,并且对于不同材料和设计的使用,替代表明原始项目提供了最合适的配置。在这项工作中获得的实验和模拟结果表明,该电离室具有合适的特性,可用于校准实验室,用于标准计算机断层扫描和放射诊断质量光束中的剂量测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号