An optimized stimulation intensity envelope for use in hemiplegic drop foot applications has been developed. The traditional trapezoidal stimulation intensity approach has been examined and found to be inconsistent with the muscle activity patterns observed in healthy gait and therefore unsuitable. Experimental functional electrical stimulation (FES)-elicited tibialis anterior (TA) electromyography (EMG) data was taken over the ankle range of interest (occurring during active dorsiflexion and loading response) while also taking into account the type of TA muscle contraction occurring (concentric, eccentric, and isometric) and the speed of hemiplegic ankle joint rotation. Using the processed data, a model of normalized EMG versus pulsewidth was developed. Implementation of this model showed the unsuitability of the trapezoidal approach in the reproducing of a natural EMG profile. An optimized stimulation intensity profile is proposed which is expected to accurately reproduce the natural TA EMG profile during gait.
机译:已经开发出用于偏瘫滴脚应用的优化刺激强度包络线。已检查了传统的梯形刺激强度方法,发现该方法与健康步态中观察到的肌肉活动模式不一致,因此不合适。实验性电刺激(FES)引起的胫前肌(TA)肌电图(EMG)数据在感兴趣的踝关节范围内(发生在主动背屈和负重反应期间)获取,同时还考虑了发生的TA肌肉收缩的类型(同心) ,偏心距和等距)以及偏瘫性踝关节旋转的速度。利用处理后的数据,建立了归一化的肌电图与脉宽的模型。该模型的实现表明梯形方法不适用于自然EMG轮廓的再现。提出了一种优化的刺激强度分布图,有望在步态中准确再现自然的TA EMG分布图。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号