Uncertainties in noise-figure and noise-parameter measurements depend to a large degree on the accuracy with which noise sources are calibrated. In some cases, the uncertainties are similar to measured quantities. This paper discusses a method for calibration of RF and microwave noise sources against a reference noise source. This method takes into account noise parameters of the receiver used for noise power measurements and includes temperature corrections to account for both drifts in the ambient temperature and heat transfer between the receiver and noise sources. Experimental results demonstrate the feasibility of the proposed method. As estimated with a Monte Carlo analysis, a $2 sigma$ uncertainty of 0.046 dB for a 5-dB excess-noise-ratio (ENR) noise source is obtained with the proposed method. This uncertainty is approximately one third of ENR uncertainties reported for commercial noise sources.
机译:噪声图和噪声参数测量中的不确定性在很大程度上取决于校准噪声源的准确性。在某些情况下,不确定性与测量数量相似。本文讨论了一种针对参考噪声源校准RF和微波噪声源的方法。该方法考虑了用于噪声功率测量的接收器的噪声参数,并包括温度校正以考虑环境温度的漂移以及接收器与噪声源之间的热传递。实验结果证明了该方法的可行性。如通过蒙特卡洛分析估计的那样,通过所提出的方法,对于5 dB的超噪比(ENR)噪声源,获得了2σ的不确定度0.046 dB。这种不确定性约为商业噪声源报告的ENR不确定性的三分之一。