...
首页> 外文期刊>Medical Imaging, IEEE Transactions on >Wide-Angle Tissue Doppler Imaging at High Frame Rate Using Multi-Line Transmit Beamforming: An Experimental Validation In Vivo
【24h】

Wide-Angle Tissue Doppler Imaging at High Frame Rate Using Multi-Line Transmit Beamforming: An Experimental Validation In Vivo

机译:使用多线传输波束形成的高帧频广角组织多普勒成像:体内实验验证。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Color tissue Doppler imaging (TDI) is a well-established methodology to assess local myocardial motion/deformation. Typically, a frame rate of can be achieved by imaging a narrow sector (, covering one cardiac wall) at moderate line density, using a dedicated pulse sequence and multi-line acquisition. However, a wide angle field-of-view is required in some clinical applications to image the whole left ventricle, which implies a drop in temporal resolution. Hereto, the aim of this study was to propose a novel imaging sequence using a multi-line transmit (MLT) beamforming approach to achieve high frame rate color TDI while preserving a wide field-of-view (i.e., 90 sector). To this end, a color MLT-TDI sequence achieving a frame rate of 208 Hz with a 90-sector was implemented on an ultrasound experimental scanner interleaved with a conventional color TDI sequence achieving the same frame rate but only with a 22.5-sector. Using this setup, the septal wall of 9 healthy volunteers was imaged and the corresponding velocity was extracted. The M-mode velocity images and the velocity profiles obtained from the MLT-TDI images presented physiologic patterns, very similar to those from conventional TDI. Moreover, for the peak systolic/diastolic velocities, good agreement and strong correlation between MLT-TDI and conventional TDI were found. The results thus demonstrate the feasibility of the novel MLT based TDI methodology to achieve high frame rate color TDI without compromising the field-of-view. This may open the opportunity to simultaneously assess regional myocardial function of t- e whole left ventricle at high temporal resolution.
机译:彩色组织多普勒成像(TDI)是用于评估局部心肌运动/变形的公认方法。通常,可以通过使用专用脉冲序列和多线采集以中等线密度对狭窄扇区(覆盖一个心脏壁)成像来获得帧速率。然而,在某些临床应用中需要广角视野以对整个左心室成像,这意味着时间分辨率下降。迄今为止,本研究的目的是提出一种使用多线发射(MLT)波束形成方法的新颖的成像序列,以在保持宽视野(即90扇区)的同时实现高帧频彩色TDI。为此,在超声实验扫描仪上实现了以90扇区实现208 Hz帧频的彩色MLT-TDI序列,该扫描仪与常规的彩色TDI序列交织,实现了相同的帧频,但仅使用22.5扇区。使用此设置,对9名健康志愿者的间隔壁进行了成像,并提取了相应的速度。 M型速度图像和从MLT-TDI图像获得的速度曲线呈现的生理模式非常类似于常规TDI的生理模式。此外,对于收缩期/舒张期峰值速度,MLT-TDI与常规TDI之间具有良好的一致性和强相关性。结果因此证明了基于新颖的基于MLT的TDI方法在不损害视场的情况下实现高帧速率彩色TDI的可行性。这可能为以高时间分辨率同时评估整个左心室的局部心肌功能提供了机会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号