首页> 外文期刊>Magnetics, IEEE Transactions on >Calculation of Radial Forces in Cage Induction Motors at Start—The Effect of Rotor Differential
【24h】

Calculation of Radial Forces in Cage Induction Motors at Start—The Effect of Rotor Differential

机译:笼式感应电动机启动时的径向力的计算-转子差动的影响

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, the radial forces in an induction motor are calculated using finite element analysis. These radial forces (or unbalanced magnetic pull-UMP) are generated when the rotor is eccentric. The work illustrates the importance of higher winding harmonics and rotor differential leakage in the starting UMP. Examples of a 6 pole machine with 26 and 40 bar rotors show that increasing the bar number and air-gap length will reduce the UMP. Further studies are carried out using parameter variation and a 10-pole machine is also addressed, where experimental results exist, in order to validate the calculation.
机译:在本文中,感应电动机中的径向力是使用有限元分析来计算的。当转子偏心时会产生这些径向力(或不平衡的磁拉动UMP)。这项工作说明了在启动UMP中较高的绕组谐波和转子差分泄漏的重要性。带有26和40 bar转子的6极电机的示例表明,增加bar数和气隙长度将减少UMP。为了验证计算结果,使用参数变化进行了进一步研究,并提出了存在实验结果的10极电机。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号