首页> 外文期刊>IEEE Transactions on Magnetics >Inductive method for AC and DC testing, creation and testing of installations
【24h】

Inductive method for AC and DC testing, creation and testing of installations

机译:交流和直流测试,装置创建和测试的感应方法

获取原文
获取原文并翻译 | 示例
           

摘要

High values of critical current multiwire superconducting cables make it impossible to use the galvanic current input method for sample testing. This necessitates the development of an inductive method. The main advantage of this method is the relatively low cost of generating very high currents. Series of toroidal and solenoidal transformers has been developed and tested. The transformers with a steel core have been used for DC tests, and those without the steel core have been used for DC and AC tests. Currents of up to 126.3 kA (quench current DC) and 50 kA AC have been obtained. Joint resistance has been less than 10/sup -10/ Omega . The possibility of using the inductive method for the critical, quench, and recovery currents is discussed, and results obtained are presented.
机译:高临界电流多线超导电缆的值使得无法使用电流输入法进行样品测试。这需要开发归纳法。这种方法的主要优点是产生很高电流的成本相对较低。已开发和测试了一系列环形和螺线管变压器。具有钢芯的变压器已用于直流测试,而没有钢芯的变压器已用于DC和AC测试。已获得高达126.3 kA(直流淬火电流)和50 kA AC的电流。关节阻力一直小于10 / sup -10 /Ω。讨论了将电感方法用于临界,淬火和恢复电流的可能性,并给出了获得的结果。