摘要

When an elevator emergency stop device is in operation, large deceleration is generated in the elevator cage. Passengers in the elevator cage sometimes get injured, because the deceleration by the elevator emergency stop device is outrageous. Therefore, the authors focused on the passengers' safety in elevators and proposed an emergency stop device with a spring and a magnetic rheological fluid (MRF) damper, which makes it possible to continuously vary its damping coefficient by controlling the magnetic field. To control the magnetic field, current of a coil surrounding the damper must be regulated. Since this type of emergency stop device is a nonlinear system, a suitable control input must be theoretically formulated. In this paper, a nonlinear controller suitable for MRF damper was designed and its control effectiveness in elevators was confirmed by digital simulations.
机译:当电梯紧急停止装置运行时,在电梯轿厢中产生大的减速度。电梯轿厢中的乘客有时会受伤,因为电梯紧急停止装置的减速令人难以忍受。因此,作者关注电梯中的乘客安全,并提出了一种带有弹簧和磁流变液(MRF)阻尼器的紧急停止装置,该装置可以通过控制磁场来连续改变其阻尼系数。为了控制磁场,必须调节阻尼器周围的线圈电流。由于这种紧急停止设备是非线性系统,因此必须在理论上制定适当的控制输入。本文设计了一种适用于MRF阻尼器的非线性控制器,并通过数字仿真验证了其在电梯中的控制效果。