...
首页> 外文期刊>IEEE Transactions on Geoscience and Remote Sensing >Correction of single frequency altimeter measurements for ionosphere delay
【24h】

Correction of single frequency altimeter measurements for ionosphere delay

机译:校正单频高度计测量电离层延迟

获取原文
获取原文并翻译 | 示例

摘要

This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the Global Positioning System (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a Sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatological model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of TIP tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to within a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.
机译:这项研究是对各种电离层模型的准确性进行的初步分析,以校正电离层路径延迟的单频高度计高度测量。特别是,研究的重点是使用来自全球定位系统(GPS)的总电子含量(TEC)数据,在参数化的实时电离层规范模型(PRISM)1.2中调整经验和参数化的电离层模型。用于调整PRISM的GPS数据类型包括映射到垂直线的GPS视距(LOS)TEC数据,以及在太阳固定的经度帧中由GPS导出的TEC数据的网格。将调整后的PRISM TEC值以及气候模型IRI-90的预测与双频测高仪针对多个TIP轨迹的TOPEX / Poseidon(T / P)TEC测量进行比较。当使用GPS LOS数据进行调整时,PRISM经验模型将在给定的本地时间内在24个1 h数据集上预测TEC,以在以午夜为中心的电离层中的8.60 TECU rms和以中午为中心的电离层的9.74 TECU rms的全局误差内。使用GPS导出的太阳固定TEC数据,PRISM参数化模型可预测TEC,误差以午夜为中心的8.47 TECU rms和中午为12.83 TECU rms。从这些最佳结果来看,很明显,即使GPS地面站的数量大大增加,并且采用任何可实现的组合,对于TOPEX / Poseidon后续跟踪系统,建议的3-4 TECU全球有效值的要求也将很难满足。前述模型或数据同化方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号