首页> 外文期刊>IEE proceedings. Part G >Optimisation of signal phase split in vector modulator phase shifters
【24h】

Optimisation of signal phase split in vector modulator phase shifters

机译:矢量调制器移相器中信号相分离的优化

获取原文
获取原文并翻译 | 示例
           

摘要

Choosing a phase split larger than 90 degrees influences the output characteristics of a vector modulator operated as a continuous phase shifter. It is shown that for a vector modulator with a phase split larger than 90 degrees , less amplitude variation is required to achieve a specified phase range as compared to a conventional design with a split of 90 degrees . Analytical expressions are given for phase and amplitude errors in the output signal resulting from errors in the phase split and amplitude of the signal vector components. By assuming simple models for errors in the signal components, the authors have performed calculations showing that a larger phase split reduces phase errors, although amplitude errors might be larger. In addition, the overall maximum power gain is reduced as the square sine of the phase split, leaving a trade-off.
机译:选择大于90度的相分离会影响用作连续移相器的矢量调制器的输出特性。结果表明,与具有90度分相的传统设计相比,对于相位分裂大于90度的矢量调制器,实现指定的相位范围所需的振幅变化较小。给出了输出信号中相位和幅度误差的解析表达式,该误差由信号矢量分量的相分离和幅度误差引起。通过假设信号分量误差的简单模型,作者进行了计算,结果表明,尽管幅度误差可能更大,但较大的相分离可减小相位误差。另外,总的最大功率增益随着相位的平方正弦减小而降低,需要进行权衡。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号