首页> 外文期刊>Hydro review >Correcting Trashrack Failure at a Pumped-Storage Plant
【24h】

Correcting Trashrack Failure at a Pumped-Storage Plant

机译:纠正抽水蓄能工厂的履带失效

获取原文
获取原文并翻译 | 示例
           

摘要

After the December 2005 failure of the 450-MW Taum Sauk Pumped-Storage plant, Ameren Missouri personnel discovered portions of the draft tube trashracks from the lower reservoir while cleaning out the tailrace. An investigation indicated the failures, brought on by corrosion-accelerated fatigue, occurred at the area experiencing the highest velocities during generation. A new trashrack design was developed, and the new trashracks were placed into service when the plant began operating in 2010. The trashracks have operated reliably, with no indications of cracking or degradation.
机译:2005年12月,450兆瓦Taum Sauk抽水蓄能电站发生故障后,密苏里州Ameren的工作人员在清理尾水时从下部水库中发现了一部分引流管垃圾箱。调查表明,由腐蚀加速疲劳引起的故障发生在发电过程中速度最高的区域。开发了新的垃圾桶设计,并且该新垃圾桶在工厂于2010年开始运营时投入使用。垃圾桶运行可靠,没有开裂或降解的迹象。