首页> 外文期刊>High Technology Letters >Thermal Performance Test of the Hot Gas Duct of 10MW High Temperature Reactor Test Module
【24h】

Thermal Performance Test of the Hot Gas Duct of 10MW High Temperature Reactor Test Module

机译:10MW高温反应堆测试模块热风管热性能测试

获取原文
获取原文并翻译 | 示例
           

摘要

The thermal performance test of the horizontal coaxial double tube hot gas duct (HGD) with an internal thermal insulation for the 10MW High Temperature Reactor Test Module (HTR-10) was conducted on a Helium Test Loop (HETL). The present paper deals with the technical feature of the HETL, the test section and the thermal performance test of the HGD. The HGD test section with a triple tube structure includes an inner heater, a HGD model and a cold-hot gas mixer. A counter-flow of cold and hot helium gas under the pres- sure of about 3.0 MPa and the minimum temperature of 100℃ in the annular passage and the maximum of 950℃ in the central tube of the HGD model was formed.
机译:在氦气测试回路(HETL)上对带有10MW高温反应堆测试模块(HTR-10)的内部绝热材料的水平同轴双管热气导管(HGD)进行了热性能测试。本文论述了HETL的技术特点,HGD的测试部分和热性能测试。具有三重管结构的HGD测试部分包括一个内部加热器,一个HGD模型和一个冷热气体混合器。在HGD模型中,在约3.0 MPa的压力,环形通道的最低温度为100℃,中心管的最高温度为950℃的条件下,形成了冷热氦气的逆流。