首页> 外文期刊>Heat Transfer Asian Research >Planning the Optimum Cleaning Schedule Based on Simulation of Heat Exchangers under Fouling
【24h】

Planning the Optimum Cleaning Schedule Based on Simulation of Heat Exchangers under Fouling

机译:基于结垢条件下换热器模拟的最佳清洗计划

获取原文
获取原文并翻译 | 示例

摘要

An investigation of variations in outlet temperatures of heat exchangers under fouling was carried out. The simulation of heat exchangers was performed by employing a linear fouling deposit function. The formation of deposits reduces heat exchangers effectiveness. There is inherently a linear nature between outlet and inlet temperatures of heat exchangers. The outlet temperatures can also be affected by up-stream exchangers serving the same streams, and the up-stream influence can be transferred in the heat system. The mathematical model of the cleaning cycle was outlined, based on the objective function of minimizing cost in unit operation time. According to the results, some heat exchangers can be given cleaning priority when the system is shut down, in order to maximize economic benefit.
机译:研究了结垢时热交换器出口温度的变化。热交换器的模拟是通过使用线性污垢沉积函数进行的。沉积物的形成降低了热交换器的效率。热交换器的出口温度和入口温度之间固有地具有线性性质。出口温度还可能受到服务于同一物流的上游交换器的影响,并且上游影响也可以在供热系统中传递。基于最小化单位运行时间成本的目标函数,概述了清洗周期的数学模型。根据结果​​,可以在关闭系统时优先考虑对某些热交换器进行清洁,以最大程度地提高经济效益。

著录项

  • 来源
    《Heat Transfer Asian Research》 |2012年第1期|p.33-42|共10页
  • 作者单位

    School of Chemical Engineering and Energy, Zhengzhou University, China;

    School of Chemical Engineering and Energy, Zhengzhou University, China;

    School of Chemical Engineering and Energy, Zhengzhou University, China;

    School of Chemical Engineering and Energy, Zhengzhou University, China;

  • 收录信息 美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    heat exchanger; cleaning schedule; fouling;

    机译:热交换器;清洁时间表;结垢;