The Effect of Square Tube Location in a Vertical Array of Square Tubes on Natural Convection Heat Transfer

机译:方管垂直阵列中方管位置对自然对流换热的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Experimental investigation is reported on natural convection heat transfer from the outer surface of a vertical array of horizontal square tubes in air. Five tubes equally spaced are used with cross section 0.02 × 0.02 m~2. The tubes are subject to constant heat flux boundary condition using internal constant heat flux heating elements in the range 46-510 W/m~2. Experiment is done for arrays of 2-5 square tubes and for four center-to-center separation distance to hydraulic diameter ratios. Study is concentrated on the effect of tube location in the array and on the geometry of the array. Results show that the downstream tubes exhibit reduced Nusselt numbers than that of a single tube for small center-to-center separation ratio of 2.5. This reduction depends on the location of the tube in the array and the number of tubes in each array. Results also show that as the ratio increases, enhancement in heat transfer over that of a single tube is observed and critical ratio is obtained at a specified value of the modified Rayleigh number for the upper (downward) tubes in each array. Local circumference averaged correlations are proposed for the upper tubes in each array and for any other individual tube in each array geometry. An overall general averaged correlation is also reported for each tube in the array.
机译:关于空气从水平方管垂直阵列的外表面进行自然对流传热的实验研究报道。使用五个等间距的管,其横截面为0.02×0.02 m〜2。使用内部恒定热通量加热元件在46-510 W / m〜2的范围内对管子施加恒定热通量边界条件。对2-5个方管的阵列以及四个中心到中心的分离距离与水力直径之比进行了实验。研究集中在管在阵列中的位置以及阵列的几何形状上。结果表明,下游中心管的Nusselt数比单个中心管的Nusselt数小,中心距比为2.5。这种减少取决于管在阵列中的位置以及每个阵列中管的数量。结果还表明,随着比率的增加,观察到的传热比单个管的传热增强,并且在每个阵列中的上(下)管的修正瑞利数的指定值处获得临界比率。对于每个阵列中的上部管以及每个阵列几何中的任何其他单个管,提出了局部圆周平均相关性。还报告了阵列中每个管的总体总体平均相关性。

著录项

  • 来源
    《Heat Transfer Engineering》 |2018年第12期|1036-1051|共16页
  • 作者单位

    Mechanical Engineering Department, King Saud University, Riyadh, Saudi Arabia;

    Mechanical Engineering Department, King Saud University, Riyadh, Saudi Arabia;

    Mechanical Engineering Department, King Saud University, Riyadh, Saudi Arabia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 04:07:11

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号