首页> 外文期刊>Gefahrstoffe - Reinhaltung der Luft >Influence of the temperature in the post-combustion chamber of cremators on the CO concentration in the exhaust gas
【24h】

Influence of the temperature in the post-combustion chamber of cremators on the CO concentration in the exhaust gas

机译:火化炉后燃烧室温度对废气中CO浓度的影响。

获取原文
获取原文并翻译 | 示例

摘要

A detailed chemical kinetic model was used to simulate the CO content in the exhaust gas of crematories under process-typical conditions. It was presumed that oxidation of CO to CO2 essentially takes place in the post-combustion chamber. A qualitative relation between CO content, O-2 content, and temperature that was taken from the literature could be confirmed and quantified. From the calculations, it follows that maintenance of the legal minimum temperature of 850 degrees C in the post-combustion chamber is necessary to comply with the CO legal emission limit of 50 mg/m(3).
机译:在过程典型条件下,使用详细的化学动力学模型来模拟火葬场废气中的CO含量。据推测,CO氧化成CO2基本上发生在后燃烧室中。从文献中得出的CO含量,O-2含量和温度之间的定性关系可以得到确认和量化。从计算中可以得出,为了遵守50 mg / m的CO法定排放限值,必须在后燃烧室内保持850℃的法定最低温度(3)。