首页> 外文期刊>Geothermics >Las Pailas geothermal binary power plant, Rincon de la Vieja,Costa Rica: Performance assessment of plant and alternatives
【24h】

Las Pailas geothermal binary power plant, Rincon de la Vieja,Costa Rica: Performance assessment of plant and alternatives

机译:哥斯达黎加Rincon de la Vieja的Las Pailas地热二元发电厂:电厂和替代品的性能评估

获取原文
获取原文并翻译 | 示例
           

摘要

A technical assessment is provided of the 35 MW (net) binary power plant at the Las Pailas geothermal field, along with three alternative designs including a simple single-flash plant and a single-flash plant combined with a bottoming binary cycle, both with and without a recuperator. The status and characteristics of the wells, the gathering system, and plant/well field layout are presented. The best producing well is the northernmost one, PGP-17, close to the Rincon de la Vieja National Park; at a wellhead pressure of 8 bar,a, it produces about 135kg/s total flow of which about 25 kg/s is steam. The unique design of the 2-unit binary power plant is discussed in detail. Plant performance is assessed based on the design specifications. Thermal and utilization efficiencies are calculated for the plant, the power cycle, the major components, as well as for the three alternative designs. Under design conditions, the Las Pailas plant has a thermal efficiency of 15.1%, a Second Law efficiency of 37.2% based on the incoming exergy of the geofluid, and a Second Law efficiency of 51.2% based on the change in exergy of the geofluid as it passes through the plant. The results of the acceptance test are presented. The analysis of data for the first 15 months of plant operation indicates that the average plant (or capacity) factor was 89.9% and the plant was available and generating power 91.6% of the time. Among the alternative designs considered, the one with the highest power output for the same geofluid inlet conditions as the actual plant was a single-flash plant optimized for peak power using the existing six production well flow curves. That alternative generated about 9.6 MW-gross more than the gross power of the actual plant, albeit at a slightly lower utilization efficiency. The highest utilization efficiency was achieved with a single-flash plant combined with a bottoming binary plant, either with or without a recuperator. No attempt was made to estimate the installed costs of the alternatives since no data were available on the actual cost to install the Las Pailas plant.
机译:对Las Pailas地热田的35兆瓦(净)二元发电厂进行了技术评估,并提供了三种替代设计,包括简单的单闪电厂和单闪电厂,并结合了有底的二元循环,包括没有换热器。介绍了井的状态和特征,收集系统以及工厂/井场布局。产量最高的井是最北端的PGP-17井,靠近Rincon de la Vieja国家公园。在8 bar,a的井口压力下,它的总流量约为135kg / s,其中蒸汽约为25kg / s。详细讨论了2单元二元电站的独特设计。根据设计规格评估设备性能。计算出电厂,电源周期,主要组件以及三种替代设计的热效率和利用率。在设计条件下,Las Pailas工厂的热效率为15.1%,根据土流体的输入能值,第二定律效率为37.2%,根据土流体的能值变化,第二定律效率为51.2%。它穿过植物。介绍了验收测试的结果。工厂运营的前15个月的数据分析表明,平均工厂(或产能)因子为89.9%,并且该工厂可用,并且在91.6%的时间内发电。在考虑的替代设计中,在与实际工厂相同的地流体入口条件下具有最高功率输出的是单闪式工厂,使用现有的六条生产井流曲线对峰值功率进行了优化。尽管利用效率略低,但该替代方案比实际电厂的总发电量多产生约9.6兆瓦的总发电量。不论有无换热器,单闪式装置与底部二元装置相结合都可实现最高利用率。由于没有关于安装拉斯派拉斯工厂的实际成本的数据,因此没有尝试估算替代品的安装成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号