The objective of this study was to develop, verify, and assess a direct shear apparatus to measure the internal shear strength of geosynthetic clay liners (GCLs) when exposed to elevated temperature and non-standard hydration solutions. Shear boxes were developed to facilitate testing 300 mm square and 150 mm square specimens. Preliminary experiments documented the effectiveness of a GCL gripping system and a two-stage hydration procedure. Direct shear experiments were performed to evaluate the new apparatus with respect to the following variables: (i) specimen size; (ii) GCL peel strength; (iii) GCL heat treatment; (iv) test temperature; and (v) hydration solution. Direct shear results were verified via comparison to literature, which also supported the use of 150 mm square GCL specimens to measure internal shear behavior and shear strength. Shear tests on heat-treated and non-heat-treated GCLs at 20 degrees C and 80 degrees C yielded a 40% reduction in internal peak strength with increase in temperature. Hydration in a high-alkaline synthetic mining solution indicated a loss in peak strength with increasing hydration times from 15 to 60 days. A systematic reduction in peak and large-displacement shear strength with increasing normal stress was observed for 60 days' hydration in the alkaline solution relative to hydration for 4 days in de-ionized water.
机译:这项研究的目的是开发,验证和评估直接剪切设备,以测量暴露于高温和非标准水化溶液中的土工合成粘土衬里(GCL)的内部剪切强度。开发了剪切盒以方便测试300毫米见方和150毫米见方的样品。初步实验记录了GCL抓取系统和两步水合程序的有效性。进行了直接剪切实验,以评估有关以下变量的新设备:(i)样品尺寸; (ii)GCL剥离强度; (iii)GCL热处理; (iv)测试温度; (v)水合溶液。通过与文献进行比较,验证了直接剪切结果,该结果也支持使用150 mm见方的GCL样品测量内部剪切行为和剪切强度。在20摄氏度和80摄氏度下对热处理和未热处理的GCL进行的剪切试验表明,随着温度的升高,内部峰强度降低了40%。在高碱性合成采矿溶液中水化表明,随着水合作用时间从15天增加到60天,峰值强度会下降。与在去离子水中水合4天相比,在碱性溶液中水合60天观察到峰值应力和大位移抗剪强度随着法向应力的增加而系统降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号