The ITER toroidal field model coil (TFMC) has been tested in the TOSK A facility of FzK. The racetrack coil, which uses a circular Nb3Sn cable-in-conduit conductor, is equipped with external resistive heaters for the evaluation of the current sharing temperature (Tcs). Since there are no sensors inside the coil, the only possibility to assess the coil temperature is to use the measured inlet temperature and to estimate the downstream propagation of the temperature profile. The analysis has shown that a quantitative assessment of Tcs from the test results of the 60 s ramp heating run tends to overestimate the cable performance compared with the strand performance.
机译:ITER环形场模型线圈(TFMC)已在FzK的TOSK A设施中进行了测试。使用圆形Nb3Sn导管内导线的赛道线圈配有外部电阻加热器,用于评估均流温度(Tcs)。由于盘管内部没有传感器,因此评估盘管温度的唯一可能性是使用测得的入口温度并估计温度曲线的下游传播。分析表明,根据60 s斜坡加热运行的测试结果对Tcs进行定量评估,往往会高估电缆性能,而不是线束性能。