首页> 外文期刊>Fusion Engineering and Design >Infrared thermography inspection of the ITER vertical target qualification prototypes manufactured by European industry using SATIR
【24h】

Infrared thermography inspection of the ITER vertical target qualification prototypes manufactured by European industry using SATIR

机译:使用SATIR对欧洲工业制造的ITER垂直目标鉴定原型进行红外热成像检查

获取原文
获取原文并翻译 | 示例
       

摘要

High heat flux loaded components which will be installed in the ITER Divertor require a heat flux removal capability in the range 5-10MW/m~2 at steady-state and up to 20MW/m~2 in transients. Within the ITER plasma facing components procurement context, each party should demonstrate its technical capability to carry out the manufacturing with the required quality. This is achieved through the successful manufacturing and testing of medium-size qualification prototypes. Each Qualification Prototype consists of three high heat flux units mounted onto an actively cooled supporting structure. Currently, the SATIR method has been identified by the ITER Organization as the basic test to decide upon the final acceptance of the ITER Divertor components. SATIR testing was performed on each CFC part of European HHF units prior to the insertion of the twisted tape and prior to assembling the units onto the steel support structure. The paper deals with SATIR results of all qualification prototypes manufactured by European industry.
机译:将安装在ITER分流器中的高热通量负载组件要求稳态下的热通量去除能力在5-10MW / m〜2范围内,瞬态时的热通量去除能力高达20MW / m〜2。在国际热核实验堆(ITER)面对等离子部件的采购范围内,各方应展示其以所需质量进行制造的技术能力。这是通过成功制造和测试中型资格原型而实现的。每个资格原型均由三个高热通量单元组成,这些单元安装在主动冷却的支撑结构上。目前,ITER组织已将SATIR方法确定为确定ITER分流器组件最终接受程度的基本测试方法。在插入扭曲带之前以及在将单元组装到钢支撑结构上之前,对欧洲HHF单元的每个CFC零件进行SATIR测试。本文讨论了欧洲工业制造的所有资格原型的SATIR结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号