首页> 外文期刊>Fusion Engineering and Design >Test result of 5 GHz, 500 kW CW prototype klystron for KSTAR LHCD system
【24h】

Test result of 5 GHz, 500 kW CW prototype klystron for KSTAR LHCD system

机译:用于KSTAR LHCD系统的5 GHz,500 kW CW原型速调管的测试结果

获取原文
获取原文并翻译 | 示例
           

摘要

A 5 GHz LHCD system is being designed for current drive and profile modification necessary for AT mode and steady-state operation of the KSTAR tokamak. A prototype 500 kW CW klystron operating at 5 GHz was developed for the steady-state RF source. In this klystron, a multi-cell cavity is introduced to reduce cavity voltage and ohmic power loss. The klystron is designed with a triode system for optimization of gain, efficiency and beam control. The high voltage for the cathode is turned by using a thyristor switching system at the low voltage transformer unit. For anode voltage control, a mod-anode voltage divider system is used which utilize the parallel-circuit of the FET switch and Zener diodes. The RF output power of the klystron was 300 kW for 800 s and 450 kW for 20 s. The maximal temperature at collector top surface was 83 C and power loss at the tube body did not exceed lOkW, the interlock level for the protection of the klystron. Detailed results of the klystron system test and commissioning are presented.
机译:正在设计一个5 GHz LHCD系统,以进行AT模式和KSTAR托卡马克稳态运行所需的电流驱动和配置文件修改。针对稳态射频源,开发了工作在5 GHz的500 kW CW速调管原型。在此速调管中,引入了多腔腔以减少腔电压和欧姆功率损耗。速调管设计有三极管系统,用于优化增益,效率和光束控制。通过在低压变压器单元上使用晶闸管开关系统来导通阴极的高压。对于阳极电压控制,使用了采用FET开关和齐纳二极管的并联电路的Mod-阳极分压器系统。速调管的射频输出功率为300 kW持续800 s,450 kW持续20 s。集热器顶表面的最高温度为83°C,管体的功率损耗不超过10kW,这是速调管保护的互锁等级。介绍了速调管系统测试和调试的详细结果。

著录项

  • 来源
    《Fusion Engineering and Design》 |2011年第8期|p.992-995|共4页
  • 作者单位

    Pohang University of Science and Technology, Pohang 790-784. Republic of Korea;

    Pohang University of Science and Technology, Pohang 790-784. Republic of Korea;

    National Fusion Research Institute. Daejeon 350-333. Republic of Korea;

    National Fusion Research Institute. Daejeon 350-333. Republic of Korea;

    National Fusion Research Institute. Daejeon 350-333. Republic of Korea;

    CEA, IRFM. F-13108 Saint-Paul-lez-Durance, France;

    CEA, IRFM. F-13108 Saint-Paul-lez-Durance, France;

    CEA, IRFM. F-13108 Saint-Paul-lez-Durance, France;

    Pohang University of Science and Technology, Pohang 790-784. Republic of Korea;

    Pohang University of Science and Technology, Pohang 790-784. Republic of Korea;

    Pohang University of Science and Technology, Pohang 790-784. Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    lower hybrid; klystron; KSTAR steady-state;

    机译:低杂种速调管KSTAR稳态;