首页> 外文期刊>Fusion Engineering and Design >Analysis of the reference accidental sequence for safety assessment of LLCB TBM system
【24h】

Analysis of the reference accidental sequence for safety assessment of LLCB TBM system

机译:LLCB TBM系统安全评估参考事故顺序分析

获取原文
获取原文并翻译 | 示例
       

摘要

Safety analysis of the reference accidental sequence has been carried out for Lead Lithium cooled Ceramic Breeder (LLCB) Test Blanket Module (TBM) system; India's prototype of DEMO blanket concept for testing in International Thermonuclear Experimental Reactor (ITER). The accidental event analyzed starts with a Postulated Initiating Event (PIE) of ex-vessel loss of first wall helium coolant due to guillotine rupture of coolant pipe with simultaneous assumed failure of plasma shutdown system. Three different variants of the sequences analyzed include simultaneous additional failures of TBM and ITER first wall, failure of TBM box resulting in to spilling of lead lithium liquid metal in to vacuum vessel and reactor trip on Loss of Coolant Accident (LOCA) signal from TBM system. The analysis address specific reactor safety concerns, such as pressurization of confinement buildings, vacuum vessel pressurization, release of activated products and tritium during these accidental events and hydrogen production from chemical reactions between lead-lithium liquid metal and beryllium with water. An in-house customized computer code is developed and through these deterministic safety analyses the prescribed safety limits are shown to be well within limits for Indian LLCB-TBM design and it also meets overall safety goal for ITER. This paper reports transient analysis results of the safety assessment.
机译:已对铅锂冷却陶瓷育种机(LLCB)测试毯模块(TBM)系统进行了参考偶然序列的安全分析;印度的DEMO毯概念原型,用于在国际热核实验反应堆(ITER)中进行测试。分析的意外事件始于假定的启动事件(PIE),该事件是由于冷却剂管道的断头台破裂而导致的第一壁氦冷却剂的前容器损失,同时假设等离子体关闭系统出现故障。所分析序列的三种不同变体包括:TBM和ITER第一壁同时发生其他额外故障,TBM箱故障导致铅酸锂金属泄漏到真空容器中以及反应器因TBM系统的冷却液事故丢失(LOCA)信号跳闸。该分析解决了特定的反应堆安全问题,例如密闭建筑物的加压,真空容器的加压,在这些偶然事件中释放的活化产物和tri,以及铅-锂液态金属和铍与水之间的化学反应产生的氢气。开发了内部定制的计算机代码,并且通过这些确定性安全分析,表明所规定的安全极限完全在印度LLCB-TBM设计的极限之内,并且还满足ITER的总体安全目标。本文报告了安全评估的瞬态分析结果。

著录项

  • 来源
    《Fusion Engineering and Design》 |2012年第6期|p.747-752|共6页
  • 作者单位

    Institute for Plasma Research, Bhat,Gandhinagar 382 428, Gujarat, India;

    Bhabha atomic Research Center, Trombay, Mumbai 400 085, Maharashtra, India;

    Institute for Plasma Research, Bhat,Gandhinagar 382 428, Gujarat, India;

    Institute for Plasma Research, Bhat,Gandhinagar 382 428, Gujarat, India;

    Institute for Plasma Research, Bhat,Gandhinagar 382 428, Gujarat, India;

    Institute for Plasma Research, Bhat,Gandhinagar 382 428, Gujarat, India;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    safety analysis; LLCB; LOCA; PIE; hydrogen limit;

    机译:安全分析;LLCB;LOCA;馅饼;氢极限;