Neutronic analysis for in situ calibration of ITER in-vessel neutron flux monitor with microfission chamber

机译:中子分析技术用于带微裂变室的ITER船载中子通量监测仪的现场校准

获取原文
获取原文并翻译 | 示例
           

摘要

Neutronic analysis is performed for in situ calibration of the microfission chamber (MFC), which is the in-vessel neutron-flux monitor at the International Thermonuclear Experimental Reactor (ITER). We present the design of the transfer system for a neutron generator, which consists of two toroidal rings and a neutron-generator holder, and estimate the effect of the system on MFC detection efficiency through neutronic analysis with the Monte Carlo N-particle (MCNP) code. The result indicates that the designed transfer system does not affect MFC detection efficiency. In situ calibrations by the point-by-point method and by the rotation method are also simulated and compared by neutronic analysis. The results indicate that the rotation method is appropriate for full calibration because the calibration time is shorter (all neutron-flux monitors can be calibrated simultaneously). However, the rotation method makes it difficult to compare the results with neutronic analysis, so the point-by-point method should be performed prior to full calibration to check the accuracy of the MCNP model.
机译:进行中子分析以对微裂变室(MFC)进行原位校准,该裂变室是国际热核实验堆(ITER)的船内中子通量监测仪。我们介绍了一个中子发生器传输系统的设计,该系统由两个环形环和一个中子发生器支架组成,并通过蒙特卡罗N粒子(MCNP)的中子分析估算了该系统对MFC检测效率的影响。码。结果表明,设计的传输系统不影响MFC的检测效率。还通过逐点法和旋转法对原位校准进行了模拟,并通过中子学分析进行了比较。结果表明,旋转方法适用于完全校准,因为校准时间较短(所有中子通量监测仪可以同时进行校准)。但是,旋转法很难将结果与中子分析相比较,因此应在完全校准之前执行逐点方法以检查MCNP模型的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号