Current status of the continuous tritium recovery test campaign using PbLi droplets in vacuum

机译:真空中使用PbLi液滴进行连续tri回收测试的现状

获取原文
获取原文并翻译 | 示例
           

摘要

This report introduces a current status of the continuous tritium recovery test campaign of PbLi droplets in vacuum, using vacuum sieve tray (VST). The campaign aims to verify the viability of VST method at a prototype design level. The following verification are to be performed. 1) Verify the steady state extraction efficiency of tritium using a 0.6 mm nozzle. The target is greater than 80%. 2) Verify the mutual interference effects on efficiency degradation by multiple droplets by comparing 1, 4, 7, and 19 nozzles. 3) Verify the reliability of VST in continuous operation. At least 24 h of non-stop operation without efficiency degradation is the primary goal, which can be extended up to 48 h. A dedicated extraction setup is to be installed March 2019 into the Oroshhi-2 PbLi experimental loop at the National Institute for Fusion Science (NIFS) Toki-Japan, followed by a stand-alone test with a short flowing period at Kyoto University which is already finished. Deuterium (D-2), instead of tritium, is used for the experiment. Extraction efficiency is calculated by comparing the D-2 concentration before-drop and after-drop. The amount of released D-2 is also measured by a quadrupole mass spectrometer (QMS) and verified by the concentration difference. The PbLi temperature is between 375 degrees C and 450 degrees C, and the flow velocity at the nozzle is between 1.5 m s(-1) and 4.5 m s(-1). The final report is scheduled to be completed by the end of 2019.
机译:本报告介绍了使用真空筛板(VST)在真空中对PbLi液滴进行连续tri回收测试的现状。该活动旨在在原型设计水平上验证VST方法的可行性。将执行以下验证。 1)使用0.6毫米喷嘴验证steady的稳态提取效率。目标大于80%。 2)通过比较1个,4个,7个和19个喷嘴,验证相互干扰对多个液滴造成的效率下降的影响。 3)验证VST在连续运行中的可靠性。主要目标是至少24小时不停机而不会降低效率,这可以延长至48小时。专门的提取装置将于2019年3月安装在日本国立融合科学研究所(NIFS)土岐日本的Oroshhi-2 PbLi实验环路中,随后在京都大学进行了短期测试的独立测试完成。实验使用氘(D-2)代替tri。通过比较滴前和滴后的D-2浓度来计算提取效率。还通过四极质谱仪(QMS)测量释放的D-2量,并通过浓度差进行验证。 PbLi温度在375摄氏度和450摄氏度之间,喷嘴处的流速在1.5 m s(-1)和4.5 m s(-1)之间。最终报告定于2019年底完成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号