首页> 外文期刊>Fusion Engineering and Design >Reviewed design of the high heat flux panels for the AUG and W7-X neutral beam calorimeter
【24h】

Reviewed design of the high heat flux panels for the AUG and W7-X neutral beam calorimeter

机译:审查了用于AUG和W7-X中性束热量计的高热通量面板的设计

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Each of the neutral beam injectors in the experimental devices ASDEX Upgrade and Wendelstein 7-X can be equipped with up to four positive ion sources with an injected neutral beam power of 2.5 MW per source. For the conditioning of the system, a movable calorimeter can be placed in the path of the neutral beam to dump the heat load. The main heat load on the calorimeter is absorbed by a set of calorimeter panels (CP). Its design, originally from 1988, specified the lifetime of the CPs to 25,000 heating cycles and ruled out any plastic deformation due to thermal cyclic loading. This was predicted with the tools available at the time but years of operation show that plastic deformation of the CPs already occurs at the very beginning of the calorimeter full power operation. After some years mechanical fatigue has led a few times to water leaks and consequently to NBI system shutdowns for repair. For this reason, careful inspection of the CPs is performed frequently and deformed CPs are exchanged for new ones.This paper presents the analysis of the causes that lead to the failure of the old CPs and proposes an optimized design for new CPs to be manufactured in the near future to substitute the old ones. The new design aims at minimizing mechanical fatigue from thermal cycling by reducing maximum surface temperature and thermomechanical stresses and improving material properties.
机译:实验设备ASDEX升级版和Wendelstein 7-X中的每个中性束注入器均可配备多达四个正离子源,每个源注入的中性束功率为2.5 MW。为了对系统进行调节,可以将可移动量热计放置在中性束的路径中,以释放热负荷。量热仪上的主要热负荷由一组量热仪面板(CP)吸收。它的设计始于1988年,规定了CP的寿命为25,000个加热周期,并排除了由于热循环载荷引起的任何塑性变形。使用当时可用的工具可以预测到这一点,但是多年的运行表明,CP的塑性变形已经在量热仪全功率运行的开始就已经发生。几年后,机械疲劳几次导致漏水,并因此导致NBI系统停机进行维修。因此,经常对CP进行仔细检查,将变形的CP更换为新的CP。本文对导致旧CP失效的原因进行了分析,并提出了针对要在其中生产的新CP的优化设计。在不久的将来取代旧的。新设计旨在通过降低最高表面温度和热机械应力并改善材料性能,最大限度地减少热循环造成的机械疲劳。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号