A preconcentration-separation procedure based on co-precipitation of palladium with thulium(Ⅲ) hydroxide has been established prior to its flame atomic absorption spec-trometric detection. The analytical parameters which are efficient on the quantitative recoveries of palladium were investigated. Palladium(Ⅱ) ions was quantitatively recovered at pH 7.5 with 2.25 mg of thulium(Ⅲ). The concomitant ions have not interference effect on the recoveries of palladium(Ⅱ). The preconcentration factor was calculated as 150. The detection limit of the presented method was calculated as 1.5 μg/L. The method was successfully applied to the determination of palladium contents of anodic slime and waste waters.
机译:在火焰原子吸收光谱法检测之前,已经建立了基于钯与氢氧化th(Ⅲ)共沉淀的预浓缩分离程序。研究了对钯的定量回收有效的分析参数。用2.25 mg的((Ⅲ)在pH 7.5下定量回收钯(Ⅱ)离子。伴随离子对钯(Ⅱ)的回收率没有干扰作用。预浓系数经计算为150。提出的方法的检出限为1.5μg/ L。该方法已成功应用于阳极泥和废水中钯含量的测定。