A novel and simple solid phase extraction method was improved and recommended for selenium. Silica gel was modified with 2,6-diamino-4-phenil-1,3,5-triazine and characterized by FTIR, SEM and elemental analysis and used adsorbent for column solid phase extraction of selenium ions. The experimental parameters (pH, flow rates, amounts of the modified silica gel, concentration and type of eluent, volume of sample, etc.) on the recoveries of selenium were optimized. Standard reference materials were analyzed for validation of method. The present method was successfully applied to the detection of total selenium in water and microwave digested some food samples with quantitative recoveries (>95%). The relative standard deviations were < 8%. Matrix influences were not observed. The adsorption capacity of modified silica gel was 5.90 mg g (1). The LOD was 0.015 mu g L (1). Enrichment factor was obtained as 50 for the introduced method. (C) 2016 Elsevier Ltd. All rights reserved.
机译:改进了一种新颖,简单的固相萃取方法,并推荐用于硒。用2,6-二氨基-4-苯基-1,3,5-三嗪对硅胶进行了改性,并通过FTIR,SEM和元素分析进行​​了表征,并用吸附剂进行了硒离子的柱固相萃取。优化了硒回收率的实验参数(pH,流速,改性硅胶的量,洗脱液的浓度和类型,样品量等)。分析标准参考物质以验证方法。本方法已成功应用于水和微波消解的一些食品样品中总硒的定量回收(> 95%)。相对标准偏差<8%。没有观察到基质的影响。改性硅胶的吸附容量为5.90 mg g(1)。 LOD为0.015μgL(1)。引入的方法的富集系数为50。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号