This paper discusses a procedure for the use of fire modelling in the performance-based design environment to quantify design fires for commercial buildings. This procedure includes building surveys, medium-and full-scale experiments and computer modelling. In this study, a survey of commercial premises was conducted to determine fire loads and types of combustibles present in these buildings. Statistical data from the literature were analysed to determine the frequency of fires, ignition sources, and locations relevant to these premises. Based on the results of the survey and the statistical analyses a number of fuel packages were designed that represent fire loads and combustible materials in commercial buildings. The fuel packages were used to perform medium- and full-scale, post-flashover fire tests to collect data on heat release rates, compartment temperatures and production and concentration of toxic gases. Based on the experimental results, input data files for the computational model, Fire Dynamics Simulator (FDS), were developed to simulate the burning characteristics of the fuel packages observed in the experiments. Comparative analysis between FDS model predictions and experimental data of HRR, carbon monoxide (CO), and carbon dioxide (CO_2), indicated that FDS model was able to predict the HRR, temperature profile in the burn room, and the total production of CO and CO_2 for medium- and large-scale experiments as well as real size stores.
机译:本文讨论了在基于性能的设计环境中使用火灾建模来量化商业建筑设计火灾的过程。该程序包括建筑测量,中型和大型实验以及计算机建模。在这项研究中,对商业场所进行了调查,以确定这些建筑物中的火灾负荷和可燃物类型。分析来自文献的统计数据,以确定火灾发生的频率,点火源和与这些场所相关的位置。根据调查结果和统计分析,设计了许多燃料包,它们代表了商业建筑中的火灾负荷和可燃材料。燃料包用于执行中型和大型,闪络后火灾测试,以收集有关放热率,舱室温度以及有毒气体的产生和浓度的数据。根据实验结果,开发了用于计算模型的输入数据文件Fire Dynamics Simulator(FDS),以模拟在实验中观察到的燃料包的燃烧特性。 FDS模型预测与HRR,一氧化碳(CO)和二氧化碳(CO_2)的实验数据之间的比较分析表明,FDS模型能够预测HRR,燃烧室的温度曲线以及CO和用于中型和大型实验以及实际存储的CO_2。

著录项

  • 来源
    《Fire Technology》 |2011年第4期|p.1081-1100|共20页
  • 作者单位

    Department of Civil and Environmental Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON K1S 5B6, Canada;

    Department of Civil and Environmental Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON K1S 5B6, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    performance-based design; design fires; modelling; experiments; commercial premises;

    机译:基于性能的设计;设计火灾;造型;实验;商业场所;