Recently, Magnesium Oxide (MgO) board has been widely used in LSF wall systems because of its improved acoustic properties, impact resistance, structural strength and serviceability. However, their thermal properties and fire performance have not been fully investigated. Therefore, in this research study thermal properties of two different types of MgO boards available in Australia were measured and their fire performance was investigated using three full-scale fire tests of LSF walls lined with two types of MgO board. Although the tests were conducted on two different types of MgO boards with different configurations, the fire test results gave a fire resistance level (FRL) of 30 min, in which the failure was initiated by integrity of the board with either board cracking or board joint opening. This paper presents the details of the thermal property tests and the three full-scale fire tests, and their results. In addition, the effects of different MgO boards, joint configurations and compounds, noggings, screw fastening techniques and cavity insulation on the fire performance of LSF walls are also presented.
机译:近年来,氧化镁(MgO)板由于其改善的声学性能,耐冲击性,结构强度和适用性而被广泛用于LSF墙体系统。但是,它们的热性能和防火性能尚未得到充分研究。因此,在这项研究中,对澳大利亚提供的两种不同类型的MgO板的热性能进行了测量,并使用衬有两种类型的MgO板的LSF墙进行了三个全面的防火测试,研究了它们的防火性能。尽管测试是在具有不同配置的两种不同类型的MgO板上进行的,但耐火测试结果显示耐火等级(FRL)为30分钟,其中故障是由于板开裂或板接合处的完整性引起的开幕。本文介绍了热性能测试和三个全尺寸防火测试的详细信息及其结果。此外,还介绍了不同的MgO板,接头结构和化合物,凸榫,螺钉紧固技术和空腔绝缘对LSF墙的防火性能的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号