Influence of fire intensity, fire impingement area and internal pressure on the fire resistance of composite pressure vessels for the storage of hydrogen in automobile applications

机译:火强度,灭火面积和内部压力对汽车应用氢气蓄电池耐火性的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The structural integrity of fully wrapped type IV hydrogen tanks is sensitive to fire. Fire damage may result in a structural failure if no pressure relief occurs. To contribute to a better understanding of the tank behavior, influencing factors on the fire resistance have to be identified. Influence of fire temperature, size of the fire impingement area and initial hydrogen pressure on fire resistance is investigated and reported quantitatively. The main result of the bonfire tests with 7.5 L tanks is that the higher the tank surface temperature, the larger the fire impingement area and the higher the initial hydrogen pressure, the shorter the fire resistance time will be.
机译:完全包装型IV氢气箱的结构完整性对火敏感。如果没有发生压力释放,火灾可能会导致结构性故障。为了更好地理解坦克行为,必须识别耐火性的影响因素。研究和报告了火灾温度,灭火面积大小和初始氢气压力的影响。篝火试验用7.5升坦克的主要结果是,罐式温度越高,耐火面积越大,初始氢气压力越高,耐火电阻时间越短。